Description
FULFILLED BY:
The Advanced Features (AF) Dimmer Module is designed for use in Sensor®+ Dimming Series modular rack enclosures. Advanced Features Dimmer Modules enable dimmer-specific feedback of load circuit data while performing digital phase angle dimming in AF-capable Sensor+ dimmer enclosures. The high-density, dimmer modules feature modular installation and removal, fully magnetic circuit breakers and enhanced risetime toroidal filters.
APPLICATIONS • Incandescent lighting • Low voltage lighting • Quartz lighting • Neon lighting • Cold Cathode lighting • 2-wire Fluorescent ballast • 4-wire Fluorescent ballast
FEATURES • Voltage, current, and temperature sensors in each dimmer • D15AF and D20AF modules are dual density • D50AF modules are single density • D100AF modules are half density • Dual back-to-back SCRs for each circuit • 500μS risetime toroidal filters • High-density modular assembly • Die-cast aluminum chassis • Fully magnetic circuit breakers
General • 100,000A Short Circuit Current Rating (SCCR) • UL and cUL LISTED
SPECIFICATIONS:
GENERAL • UL and cUL Listed for continuous duty at 100% of rated load • D15AF – 1.8kW • D20AF – 2.4kW • D50AF – 6.0kW • D100AF – 12.0kW
PHYSICAL • Modular plug-in assemblies • Cast aluminum chassis, finished with textured epoxy paint • Keyed to prevent insertion in inappropriately rated rack positions
CIRCUIT BREAKERS • Fully magnetic to eliminate nuisance tripping • 20x inrush current rating • 125%, 10-120 seconds, must-trip rating • Rated for 100% switching duty applications
RATINGS • 100,000A Short Circuit Current Rating (SCCR) • Modules withstand hot-patching of cold loads up to full rating
Power Device • Sealed, patented assembly • Field replaceable with screwdriver • Two back-to-back SCRs per circuit • One control LED and one output LED per circuit • Integral bonded heatsink • Integral temperature sensor • Built-in voltage and current sensors
FILTERING • High quality 500μS risetime* toroidal filters * Risetime measured at full load, at worst case firing angle (90 degrees), from 10-90% of output wave form
DIMMER RANGE • Incandescent, low voltage dimming range 100-0% • Dimming range of 2 and 4-wire fluorescent ballast is dependent on lamp ballast combination. Contact ETC for range verification • Sizing of Neon transformer used in dimming applications should be 1.5x greater than size used in non-dimming application